Atualizando informações ...

INVERSOR DE FREQUÊNCIA 220KW 380 480V - ATV930C22N4C

Marca: Schneider Referência: ATV930C22N4C

Preço sob Consulta

Efetue Cotação
Não disponível

Enviar
Avise-me quando estiver disponível
Descrição Geral
<table class="specifications-table" style="box-sizing: inherit; font-size: 14px; line-height: 20px; font-weight: 400; color: rgb(51, 51, 51); width: 780px; height: auto; border-collapse: collapse; max-width: 980px;"> <tbody style="box-sizing: inherit;"> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">Linha de produto</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">Altivar Process ATV900</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">Aplicação do dispositivo</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">Aplicação indústrial</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">Tipo de produto ou componente</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">Propulsor de velocidade variável</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">Destino do produto</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">Motores síncronos<br style="box-sizing: inherit;" /> Motores assíncronos</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">aplicação específica do produto</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">Process for industrial</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">variante</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">Versão padrão<br style="box-sizing: inherit;" /> Sem trinco picador</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">número de rede de fases</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">Trifásico</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">Modo de montagem</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">Wall Mount</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">Protocolo da porta de comunicação</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">Modbus serial<br style="box-sizing: inherit;" /> Ethernet/IP<br style="box-sizing: inherit;" /> Modbus TCP</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">tensão nominal de fornecimento [Us]</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">380 ... 480 V - 15...10 %</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">alimentação do motor kW</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">220,0 kW of direito normal<br style="box-sizing: inherit;" /> 160,0 kW of trabalho pesado</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">alimentação do motor cv</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">350,0 hp of direito normal<br style="box-sizing: inherit;" /> 250,0 hp of trabalho pesado</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">corrente de saída contínua</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">302 A a 2,5 kHz of trabalho pesado<br style="box-sizing: inherit;" /> 427 A a 2,5 kHz of direito normal</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">filtro EMC</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">Integrado<br style="box-sizing: inherit;" /> With EMC plate option</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">grau de protecção IP</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">IP21</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">grau de proteção</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">UL tipo 1</span></td> </tr> <tr class="specifications-table__row" style="box-sizing: inherit; border-bottom: 1px solid rgb(231, 230, 230); display: flex; flex-direction: row; padding: 14px 0px;"> <th class="specifications-table__row-heading" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 15px; width: 251.938px; text-align: left;">option module</th> <td class="specifications-table__cell" style="box-sizing: inherit; vertical-align: top; white-space: normal; padding: 0px 0px 0px 24px; max-width: 67.7%; text-align: left;"><span class="specifications-table__text specifications-table__text--first-letter-uppercase" style="box-sizing: inherit; display: inline-block;">Slot A: módulo de comunicação of Profibus DP V1<br style="box-sizing: inherit;" /> Slot A: módulo de comunicação of Profinet<br style="box-sizing: inherit;" /> Slot A: módulo de comunicação of DeviceNet<br style="box-sizing: inherit;" /> Slot A: módulo de comunicação of EtherCAT<br style="box-sizing: inherit;" /> Slot A: módulo de comunicação of "daisy chain" CANopen RJ45<br style="box-sizing: inherit;" /> Slot A: módulo de comunicação of CANopen SUB-D 9<br style="box-sizing: inherit;" /> Slot A: módulo de comunicação of CANopen terminais de parafuso<br style="box-sizing: inherit;" /> Ranhura A/ ranhura B/ ranhura C: módulo de extensão analógico e digital I / O<br style="box-sizing: inherit;" /> Ranhura A/ ranhura B/ ranhura C: módulo de extensão de relé de saída<br style="box-sizing: inherit;" /> Ranhura B: 5/12 V módulo de interface de codificador digital<br style="box-sizing: inherit;" /> Ranhura B: módulo de interface de codificador analógico<br style="box-sizing: inherit;" /> Ranhura B: módulo de interface do codificador resolver<br style="box-sizing: inherit;" /> módulo de comunicação of Ethernet Powerlink</span></td> </tr> </tbody> </table> <p> </p>
Avaliações

Produtos visualizados

Carregando ...